Shanghai Journal of Stomatology ›› 2021, Vol. 30 ›› Issue (2): 135-139.doi: 10.19439/j.sjos.2021.02.005

• Original Articles • Previous Articles     Next Articles

Accuracy of implantation between two immediate implantation methods in mandibular molars

MU Hai-zhang1, WANG Wen-chao1, YANG Pei-ming1, ZHANG Yong-ya2, HUANG Hui2, ZHANG Shan-yong3   

  1. 1. College of Stomatology, Weifang Medical University. Weifang 261053, Shandong Province;
    2. Department of Radiology, Shanghai Ninth People’s Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine. Shanghai 200001;
    3. Department of Oral Surgery, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine; Shanghai Key Laboratory of Stomatology. Shanghai 200011,China
  • Received:2020-07-31 Revised:2020-12-02 Online:2021-04-25 Published:2021-05-11

Abstract: PURPOSE: To compare the accuracy of implant placement between modified and traditional immediate implant placement in mandibular molar regions. METHODS: Twenty-four patients were selected for immediate implantation in the molar area including 24 implantation sites. Preoperative cone-beam CT(CBCT) was conducted and then digital software Simplant 18.0 was used to design the ideal three-dimensional position of the implants. In the experimental group, the implant socket was prepared first according to reference of the remaining natural teeth, then the implant was implanted after minimally invasive extraction. Twelve patients in the control group underwent immediate implantation by traditional immediate implant procedures. Minimally invasive extraction, then socket preparation, and final implanting were performed. All patients underwent CBCT after surgery. Implant sites designed prior to surgery and actual implant sites differences between modified and traditional immediate implant placement were measured by Simplant 18.0 and compared with SPSS 17.0 software package. RESULTS: In the experimental group and control group, the measured average deviation were as follows, the angle was (4.492±0.912)° and (7.255±1.307)°, respectively; The horizontal error of the implant shoulder was (0.379±0.083) mm and (1.229±0.270) mm, respectively; The measuring horizontal error of the implant apex was (1.263±0.267) mm and (2.183±0.264) mm, respectively; The calculative horizontal error of the implant apex was (1.324±0.203) mm and (2.709±0.383) mm, respectively; Depth error of the implant apex was (0.663±0.123) mm and (1.533±0.155) mm, respectively, which were significantly lower than those of the control group. CONCLUSIONS: Compared with the traditional method, modified immediate implantation can improve the accuracy of implantation in mandibular molars.

Key words: Immediate implant placement, Accuracy, Digital software